Usage Data
Access to usage data for location
Delivery Mode = Direct Admix
Admix #
Metering Output
Digital output address of port used to operate the metering device
Pulse Meter Signal
Digital input address of port used to receive the meter pulse
Pulse Counter SP
Pulse counting setpoint number
Usage Data
Access to usage data for location
Delivery Mode = Reservoir Water
Water #
Water counter number
Fill Reservior
Digital output address of port used to fill the reservoir
Reservior Discharge
Digital output address of port used to discharge the reservoir
Tailwater Discharge
If a separate tailwater reservoir compartment exists, digital output address of
port used to discharge the reservoir tailwater
Reservior Empty Sensor
Digital input address of port used to receive the reservoir empty signal
Pulse Meter Signal
Digital input address of port used to receive the meter pulse. This must be the
same as the digital
Input counted by the setpoint specified in the next (Pulse Counter SP)
parameter
Pulse Counter SP
Pulse counting setpoint number
Usage Data
Access to usage data for location
Delivery Mode = Direct Water
Water #
Water counter number
Metering Output
Digital output address of port used to operate the metering device
Pulse Meter Signal
Digital input address of port used to receive the meter pulse
Pulse Counter SP
Pulse counting setpoint number
Usage Data
Access to usage data for location
Location Usage Data
Daily Material Used
Daily Dispensed Accumulator
Weekly Material Used
Weekly Dispensed Accumulator
Monthly Material Used
Monthly Dispensed Accumulator
Yearly Material Used
Yearly Dispensed Accumulator
Material On Hand
Material on Hand
Last Daily Reset Time
Time and date daily material accumulator most recently reset
Last Weekly Reset Time
Time and date weekly material accumulator most recently reset
Last Monthly Reset Time
Time and date monthly material accumulator most recently reset
Last Yearly Reset Time
Time and date yearly material accumulator most recently reset
Scales Select or Enter scale number. 1-Agg, 2-Cement
Level 4 Sub-menu ADMIN MENU/APPLICATION PARAMETERS/DATABASES/SCALES
Scale Number
ID number used to reference this scale.
Name
Scale name (30 characters maximum)
Capacity
Maximum scale capacity
Scale Type
Hopper
Decumulative
Select the type of scale – either hopper or decumulative. Hopper scales
operate by discharging a material into the hopper until the target weight has
been reached and then dumping the hopper into the truck or mixer.
A decumulative scale has the full bin or bins on the scale and discharges the
correct amount of material(s) directly into the truck or mixer.
ADMIN Menu
Parameter
Choices
Description