32
Installation/Operation Manual
Jogging
Jogging is used to add small increments of material to reach or exceed the target weight.
The jog levels are used to adjust the amount of time the open gate control will be held on depending on how
far we are from the target weight.
If we are within the Jog Tolerance, no jogging will be done. Otherwise, the distance from the target will be
used to determine the jog level, and the jog level is used to determine how much time (0.00 to 0.80 seconds)
is to be added to the minimum jog time to determine the actual jog time.
Jog Mode
Off
On
Used to disable / enable jogging
Maximum Number of Jogs
10
Maximum number of jogs allowed
Jog Off Time
2.00
Settling time between jogs. This is the amount of time it takes for the jogged
material to arrive on the scale.
Jog Tolerance Weight
20
No Jog target tolerance weight
SS Flow Rate
0
Unused
Minimum Jog Time
0.25
Minimum jog on interval in seconds
Maximum Jog Time
1.5
Maximum jog time in seconds
Level 1 Jog Weight
50
Maximum remaining weight for jogging at minimum jog time
Level 2 Jog Weight
150
Maximum remaining weight for jogging at minimum jog time + 0.05 seconds
Level 3 Jog Weight
Maximum remaining weight for jogging at minimum jog time + 0.10 seconds
Level 4 Jog Weight
200
Maximum remaining weight for jogging at minimum jog time + 0.15 seconds
Level 5 Jog Weight
300
Maximum remaining weight for jogging at minimum jog time + 0.20 seconds
Level 6 Jog Weight
400
Maximum remaining weight for jogging at minimum jog time + 0.25 seconds
Level 7 Jog Weight
500
Maximum remaining weight for jogging at minimum jog time + 0.30 seconds
Level 8 Jog Weight
600
Maximum remaining weight for jogging at minimum jog time + 0.35 seconds
Level 9 Jog Weight
700
Maximum remaining weight for jogging at minimum jog time + 0.40 seconds
Level 10 Jog Weight
800
Maximum remaining weight for jogging at minimum jog time + 0.50 seconds
Level 11 Jog Weight
900
Maximum remaining weight for jogging at minimum jog time + 0.60 seconds
Level 12 Jog Weight
1000
Maximum remaining weight for jogging at minimum jog time + 0.70 seconds
Locations
You have the ability to Add, Copy, Change, Delete or Exit
Level 4 Sub-menu ADMIN MENU/APPLICATION PARAMETERS/DATABASES/LOCATIONS
Location ID
ID used to reference this location
Name
Location name
Material
Material ID of material dispensed from this location
Delivery Mode
Single Speed
Dual Speed
Dual Concurrent
Inching Gate
Bottle Admix
Direct Admix
Reservoir Water
Direct Water
Select the method used to deliver the product at this location. The setting of
this parameter will determine which of the following parameters are
presented.
Delivery Mode = Single Speed, Dual Speed, or Dual Concurrent
Secondary Mode
Off
Continuous Aeration
No Flow Aeration
Continuous Vibrator
No Flow Vibrator
Chose aeration or vibrator and whether they should be used continuously or
only when material stops flowing
Scale
Scale ID of scale used to weigh material
ADMIN Menu
Parameter
Choices
Description