Rice Lake CB-2 Concrete Batch Controller Version 2.0 User Manual
Page 31

Installation/Operation Manual - Configuration of User Parameters
27
Water Adjust per Batch
No
Yes
Yes if the water adjustment amounts are to be per batch, No if they are to be
per yard/cubic meter.
Admix System
Level 4 Sub-menu ADMIN MENU/APPLICATION PARAMETERS/ADMIX SYSTEM
Suspend Admixture Addition
No
Yes
Set this to Yes to inhibit the adding of all admixtures without changing the mix
designs.
Single Empty Signal
No
Yes
Yes if Admixture 1 Bottle Empty on indicates all bottles are empty.
Mixing System
Level 4 Sub-menu ADMIN MENU/APPLICATION PARAMETERS/MIXING SYSTEM
Enable Mixer Controls
No
Yes
Set to Yes if a mixer is part of your system and you wish to have the CB-2
control it.
Auto Start/Stop Mixer
No
Yes
If Yes, the CB-2 will control the running of the mixer.
Mixer Start is Latched
No
Yes
If Yes, the CB-2 will pulse the Mixer Start output on for two seconds to start
the mixer and pulse the Mixer Stop output to stop the mixer.
Otherwise, the Mixer Start output is set on and held on to run the mixer.
Auto Discharge Mixer
No
Yes
If Yes the CB-2 will control the discharge of the mixer.
Power Discharge Gate to Close
No
Yes
If Yes, CB-2 will set the Mixer Gate Close output on to close the mixer
discharge gate.
Discharge Gate Close Time
3.0
Time in seconds for the mixer discharge gate to open/close. If Power
Discharge Gate to Close was set to Yes, this is the amount of time the Mixer
Gate Close output will be held on. If Gate Open Limit Switch is set to No and
Power Discharge Gate to Close to Yes, this is the amount the Mixer Gate
Open output will remain on to open the gate.
Mixer Discharge Time
8.0
Maximum time in seconds for the mixer to discharge.
Gate Closed Limit Switch
No
Yes
If Yes, CB-2 will use the Mixer Gate is Closed input to recognize that the gate
is closed.
Gate Open Limit Switch
No
Yes
If Yes, CB-2 will use the Mixer Gate is Open input to recognize that the gate is
open.
Ticket/Reports Setup
Level 4 Sub-menu ADMIN MENU/APPLICATION PARAMETERS/TICKETS & REPORTS SETUP
Print Custom Batch Ticket
No
Yes
Print Custom Batch Ticket (requires special software)
Print Ticket Number
No
Yes
Select Yes to print the batch ticket number on the batch ticket.
# Line Feeds
Number of initial lines to space to reach correct starting location.
DOT Header
“Certificate of Compliance”
This string will be printed at the head of any ticket printed for an order that has
it’s DOT parameter defined as other than None.
Source Length
6
Maximum printable material source length.
ADMIN Menu
Parameter
Choices
Description
Table 4-1. Application Parameters Sub-menu List