40
R E L I A N C E - I G S S I N S T A L L A T I O N M A N U A L
D.2.5 Drill #11, .191 diameter holes in D-186 subframe for FS-15 rivets. Install door stops onto subframe
with SC-1 clips at 18" O.C. Locate clips around the subframe anchor screws. SEE FIGURE 47.
Vertical stops run through.
D.2.6 Install door per DOOR AND FRAME INSTALLATION AND GLAZING MANUAL.
D.2.4 Bed threshold in sealant, attaching to TH-44 clips with FS-42, #12 x 1/2" Phillips Flat Head screws.
Marry threshold seal with subframe and main system seal. SEE FIGURE 47.
2-13/16"
DS-1 Door Stop
Drill #11 (.191 dia.) hole
in subframe @ 18" o.c.
for FS-15 rivet
FS-325 (#12-14 x 1-1/2"
HH Drill-Flex) stagger around
subframe anchor
Perimeter seal at sill
Seal around base of D-186 &
vertical; Marry this seal with
threshold & perimeter seal
Bed threshold
in sealant
FIGURE 47
Door Stop and
Threshold Installation
DOOR INSTALLATION