10 frame assy – Oldcastle BuildingEnvelope Reliance-IG SS User Manual
Page 13
10
R E L I A N C E - I G S S I N S T A L L A T I O N M A N U A L
FIGURE 8
Frame Sealant
Apply sealant along interior
and exterior faces of all
horizontal members.
Apply sealant at interior face
of horizontals. Exterior to be
sealed during installation.
FS-9
(#14 X 1-1/2 "HHSTS)
IW183-01 @ 6 1/4"
IW193-01 @ 7 1/2"
Head anchor sleeve
FS-8
(#14 X 1"HHSTS)
FS-8
(#14 X 1"HHSTS)
Apply sealant along interior
face of horizontal member.
FRAME ASSEMBLY