17 mid span anchor – Oldcastle BuildingEnvelope Reliance-IG SS User Manual
Page 20
17
R E L I A N C E - I G S S I N S T A L L A T I O N M A N U A L
Anchor type and sizes vary per job requirements. Details shown in these instructions are to be used
as a guide only. Refer to approved shop drawings for actual conditions.
3.10 Mid span anchors will be located based on engineer's calculations. Typical anchors are shown in
FIGURE 19. Size and design of anchor, as well as, bolt size and quantity to be based on project
requirements and engineer's calculations.
3.11 When glazing areas of wall requiring mid span anchors it will be necessary to exterior glaze.
Reliance-IG SS offers two exterior glazed horizontals for this purpose. The horizontal shown in FIGURE
17 is for areas where interior and exterior glazing may be required such as at the upper horizontal of an
area with mid span anchors or may be used for easy reglazing. The horizontal in FIGURE 18 is for
exterior glazed areas only and may also be used at the upper horizontal of areas with mid span anchors.
IW-549
IW-161
WW-542
IW-162
IW-151
FIGURE 17
Interior / Exterior
Glazed Horizontal
FIGURE 18
Exterior Glazed
Horizontal
SYSTEM ANCHORAGE AT MID SPAN