R E L I A N C E - I G S S I N S T A L L A T I O N M A N U A L

FIGURE 37

Adaptor at Typical

Vertical Mullion

Note: Glazing adaptors to be installed after wall has been erected and zone plugs have been installed and

sealed in place. Water testing of glazing pockets is recommended prior to installing the adaptors.

T.1 Glazing adaptors at captured vertical mullions and jambs and horizontals require the WW-145 adaptor

to be hooked into the notch (Step 1) at the mullion stem and then rotated and snapped into place

(step 2). SEE FIGURE 37

T.2 Glazing adaptor at SSG vertical mullions will be attached using FS-201 (#10 x 1 1/2" pfh) fasteners at

12" on center. Mullion will be match drilled using #11 (.191Ø) drill bit. Holes in mullion must have

sealant injected into the tap holes just prior to attaching the adaptor to the mullion.SEE FIGURE 39

T.3 All adaptors must have bead of sealant (Step 3) around the interior perimeter SEE FIGURES 37, 38,

39 & 40, sealant tooled and corner of adaptors sealed.

T.4 Exterior glazed horizontal WW-442 and WW-542 require glazing adaptor WW-175 for 1/4" glazing.

SEE FIGURE 40

FIGURE 38

Adaptor at

Typical Horizontals

STEP 2

STEP 1

STEP 3

WW-145

IW-151

WW-145

GLAZING ADAPTOR INSTALLATION