Glazing Notes:

1) Interior Gaskets: GP-113 Wedge Gasket

Exterior Gaskets: GP-123 Push-In Gasket

2) Remove gaskets from reels and allow to relax overnight before installing.

3) Cut gaskets 1/4" longer per foot of aluminum extrusion to allow for relaxation.

4.7 Install vertical face covers, then horizontal face covers leaving equal gap at the ends. Make sure

weep hole is on bottom. To prevent damaging snap-on face caps during installation, hold a short

piece of 2 x4 wood block over the cap and strike with a Stanley 3 lbs Compo-cast dead blow soft face

hammer. Strike cap at clip locations. Do not hit the face cap directly with a mallet. See Details "A".

FIGURE 28

Glazed Assembly

GP-123 Gaskets

See notes below

for installation

GP-113 Wedge Gasket

See notes below

for installation

Wood 2"X4"

block

Detail A

GLAZING INSTRUCTIONS