4 replacing the front panel board – Kontron CG2200 Carrier Grade Server User Manual
Page 72

65
Kontron CG2200 Carrier Grade Server Installation and Maintenance Guide
Figure 47. Removing a Fan from the Chassis
5. Replace the fan by inserting it into the same slot. Use the edges of the metal enclosure to align the
fan assembly properly and to make sure the power connector is seated properly in the header on the
left side of the metal enclosure.
6. If this is the last task you are performing, close the chassis cover by sliding it forward until it clicks into
place. Replace the shipping screw, if used.
5.4
Replacing the Front Panel Board
The front panel board provides the interface to the controls at the front of the server, the power
interconnect for the server board, the USB and COM2 interfaces and SD flash modules. The FP board
also houses the LED/switch board that controls the front panel LEDs and the telco alarm manager.
To replace the FP board, you must first remove the following components:
•
The chassis cover
•
The front bezel
•
The support cross bar and all components attached to it
•
The CPU1 and CPU2 power cables
•
The fan cage
•
All cable connections on the FP board
- Multifunction (power and signal, HDD LED, COM2)cable
- SSI FPB cable