beautypg.com

14 ethernet nic ports, 15 remote management module 4, 16 power supply subsystem – Kontron CG2200 Carrier Grade Server User Manual

Page 22: 17 system cooling

background image


15

Kontron CG2200 Carrier Grade Server Installation and Maintenance Guide

Table 3. Riser Card Configuration Options

Riser Card Option

Slot Configuration

PCI Express passive riser single slot x16
Right-side riser (baseboard slot 5)

Single full-height PCI Express connector

PCI Express passive riser dual slot x8
Right-side riser (baseboard slot 5)

Two full height PCI Express x8 connectors

PCI Express/PCI-X active riser
Right-side riser (baseboard slot 5)

Two full-height PCI-X 133 connectors

PCI Express passive riser single slot x16
Left-side riser (baseboard slot 2)

Single full-height PCI Express connector

PCI Express passive riser dual slot x8
Left side riser (baseboard slot 2)

Two Full height PCI Express x8 connectors

2.14 Ethernet NIC Ports

The S2600CO server board (baseboard) provides four dual network interface controller (NIC) RJ45
connectors oriented side-by-side on the back edge of the board and accessible at the rear I/O panel.
Additional rear-accessible GbE NIC ports can be added to the system by using full-height PCI-X/PCIe
add-in cards or low-profile PCIe add-in cards

2.15 Remote Management Module 4

RMM4 can be implemented optionally on the iBMC on the S2600CO server board. To use this feature, a
separately-orderable RMM4 kit must be installed. An RMM4Lite kit can also be purchased to enable
advanced features in the iBMC without a dedicated management NIC.

2.16 Power Supply Subsystem

The power supply subsystem consists of up to two AC or DC power supply modules (two needed for
redundancy) and a power distribution board (PDB). One power supply module is included with the server
with a filler panel in the second power supply slot.

The power supply module is rated for 650W output capability in full AC or DC input voltage range. The
minimum steady-state DC input voltage at which the equipment remains fully operational is -38 VDC. The
nominal operating voltage of the DC system is -48 VDC.

2.17 System Cooling

There are three main cooling areas in the CG2200 server as illustrated in

Figure 8.