beautypg.com

Kontron CG2200 Carrier Grade Server User Manual

Page 42

background image


35

Kontron CG2200 Carrier Grade Server Installation and Maintenance Guide

Table 5. Server Board Jumpers (J1E2, J1E4, J1E3, J1E6, J2J2)

Jumper Name

Pins

System Results

J1E2: Password
Clear

1 - 2

These pins should have a jumper in place for normal system operation
(Default)

2 - 3

To clear administrator and user passwords, power on the system with
pins 2 – 3 connected. The administrator and user passwords clear in 5 –
10 seconds after power on. Pins 2 – 3 should not be connected for
normal system operation.

J1E4: BMC

Force Update

1 - 2

BMC Firmware Force Update Mode – Disabled (Default)

2 - 3

BMC Firmware Force Update Mode – Enabled

J1E3: ME

Force Update

1 - 2

ME Firmware Force Update Mode – Disabled (Default)

2 - 3

ME Firmware Force Update Mode – Enabled

J1E6: BIOS

Recovery

1 - 2

These pins should have a jumper in place for normal system operation
(Default)

2 - 3

The main system BIOS does not boot with pins 2 – 3 connected. The
system only boots from EFI-bootable recovery media with the recovery
BIOS image.

J2J2: BIOS

Default
(CMOS Clear)

1 - 2

These pins should have a jumper in place for normal system operation
(Default)

2 - 3

If these pins are connected when AC power is unplugged, the CMOS
settings are cleared within five seconds. Pins 2 - 3 should not be
connected for normal operation.

See Section 9.1, “BIOS Defaults (CMOS Clear) and Password Reset Usage Procedure” in the Intel®
Server Board S2600CO Family TPS
on the Kontron Support website for more information about the
recovery features.