beautypg.com

Dell POWEREDGE C6105 User Manual

Page 28

background image

28

|

About Your System


Error Code Error Message

Response Error Cause

Recovery

Method

4106

SPD missing byte 23 or 25 Pause

DIMM bad

Change DIMM

4107

Bank interleave requested
but not enabled

Warning DIMM bad

Change DIMM

4108

Dram ECC requested but
not enabled

Pause

DIMM bad

Change DIMM

4109

Online spare requested but
not enabled

Pause

DIMM bad

Change DIMM

410A

DIMM(s) Running in
Minimum Mode

Pause

DIMM bad

Change DIMM

410B

No DQS Receiver Enable
pass window found

Pause

DIMM bad

Change DIMM

410C

DQS Rcvr En pass window
CHA to CHB too large

Pause

DIMM bad

Change DIMM

410D

DQS Rcvr En pass window
too small (far right of
dynamic range)

Pause

DIMM bad

Change DIMM

4160

The processor(s) installed
in your system are not
multiprocessing capable.

halt

Unknown CPU

Install correct
CPU

5120

CMOS cleared by jumper Pause

CMOS clear by
jumper

No action

5121

Password cleared by jumper Pause

Password clear by
jumper

No action

8101

Warning! USB Host
Controller not found at the
specified address!!!

Warning USB Host

controller bad.

No action

8102

Error! USB device failed to
initialize!!!

Warning USB init fail.

Check the USB
device
connected.

8103

Warning! Unsupported
UBS device found and

Warning Detected an

unsupported USB

Check the USB
device