beautypg.com

Dell POWEREDGE C6105 User Manual

Page 25

background image

About Your System | 25


Error Code Error Message

Response Error Cause

Recovery

Method

000B

CMOS Memory Size
Wrong

Pause

Base memory size
error

Change DIMM
or board repair

000C

RAM Read/Write Test
Failed

Pause

No usable system
memory

Change DIMM

000E

Floppy A: Driver Error

Pause

Floppy controller
error

Board repair

000F

Floppy B: Driver Error

Pause

Floppy controller
error

Board repair

0012

CMOS Date/Time Not Set Pause

Indicate invalid
Date/Time in
CMOS diagnostic
status byte

Reset
Date/Time

0040

Refresh Timer Test Failed Halt

Unrecoverable
system-board
failure

Board repair

0041

Display Memory Test
Failed

Pause

Unrecoverable
system-board
failure

Board repair

0042

CMOS Display Type
Wrong

Pause

Unrecoverable
system-board
failure

Board repair

0044

DMA Controller Error

Halt

Unrecoverable
system-board
failure

Board repair

0045

DMA-1 Error

Halt

Unrecoverable
system-board
failure

Board repair

0046

DMA-2 Error

Halt

Unrecoverable
system-board
failure

Board repair

0047

Unknown BIOS error. Error
code = 0047

Halt

Unspecified

Board repair