Error Code
Message Information
Action
Review System Log or front panel for additional information.
HWC7008
Message
Server <
number
> health changed to a warning state from more
severe state. Server <
number
> health changed to a critical state from
a non-recoverable state.
Details
Server <
number
> health changed to a warning state from a normal
state.
Action
Review System Log or front panel for additional information.
HWC7010
Message
Server <
number
> health changed to a critical state from a
nonrecoverable state.
Details
Server <
number
> health changed to a warning state from a normal
state.
Action
Review System Log or front panel for additional information.
HWC7012
Message
Server <
number
> health changed to a nonrecoverable state.
Details
Server <
number
> health changed to a warning state from a normal
state.
Action
Review System Log or front panel for additional information.
LNK2700
Message
The <
name
> LAN heartbeat is lost.
Details
CMC has lost network connection.
Action
Check network cable and network connections.
MEM0000
Message
Persistent correctable memory errors detected on a memory device
at location(s) <
location
>.
Details
This is an early indicator of a possible future uncorrectable error.
Action
Re-seat the memory modules. If the issue persists, see
.
MEM0001
Message
Multi-bit memory errors detected on a memory device at location(s)
<
location
>.
LCD Message
Multi-bit memory error on <
location
>. Re-seat memory.
Details
The memory module has encountered a uncorrectable error. System
performance may be degraded. The operating system and/or
applications may fail as a result.
Action
Re-seat the memory modules. If the issue persists, see
.
91