Error Code
Message Information
Details
System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.
Action
1. Review system logs for power supply exceptions.
2. Remove the processor module. Inspect processor socket for
bent pins.
VLT0200
Message
The system board <
name
> voltage is less than the lower critical
threshold.
LCD Message
System board voltage is outside of range.
Details
System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.
Action
1. Review system logs for power supply exceptions.
2. Remove the processor module. Inspect processor socket for
bent pins.
VLT0201
Message
The system board <
name
> voltage is less than the lower warning
threshold.
LCD Message
System board voltage is outside of range.
Details
System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.
Action
1. Review system logs for power supply exceptions.
2. Re-configure the system to minimum configuration, inspect and
reinstall system cables.
VLT0202
Message
The system board <
name
> voltage is greater than the upper warning
threshold.
LCD Message
System board voltage is outside of range.
128