Error Code
Message Information
Action
Review system logs for memory exceptions. reinstall memory at
location <
location
>
MEM1214
Message
Memory redundancy is degraded.
Details
The memory may not be seated correctly, misconfigured, or has
failed.
Action
Check the memory configuration. Re-seat the memory modules. If the
issue persists, see
MEM7002
Message
A hardware mismatch detected for memory riser.
LCD Message
Memory riser mismatch detected. Check memory riser.
Details
Memory riser is installed incorrectly, or failed.
Action
Check that the memory riser is installed correctly. If the issue
persists, see
.
MEM8000
Message
Correctable memory error logging disabled for a memory device at
location <
location
>.
LCD Message
SBE log disabled on <
location
>. Re-seat memory.
Details
Errors are being corrected but no longer logged.
Action
Review system logs for memory exceptions. reinstall memory at
location <
location
>.
OSE0000
Message
A critical stop occurred during OS load.
Details
The system halted due to an exception during operating system load
or operating system initialization.
Action
Review operating system logs and system video for additional
information.
OSE0001
Message
A runtime critical stop occurred.
Details
The system halted due to an exception while the operating system
was running. This is a kernel panic or bug check event.
Action
Review operating system logs and system video for additional
information.
OSE0004
Message
A soft shut-down initiated by platform event filter.
Details
A separate exception or status condition shutdown the operating
system. (IPMI sensor type 20h - offset 04h).