Dell PowerEdge M520 (for PE VRTX) User Manual
Page 93

Error Code
Message Information
MEM0010
Message
Memory device at location <
location
> is over heating.
LCD Message
Memory device <
location
> is over heating. Check fans.
Details
System performance is degraded.
Action
If unexpected, review system logs for power or thermal exceptions.
MEM0022
Message
Memory device at location <
location
> is absent.
Details
The memory may not be seated correctly, misconfigured, or has
failed. Memory size is reduced.
Action
Re-seat the memory modules. If the issue persists, see
.
MEM0701
Message
Correctable memory error rate exceeded for <
location
>.
Details
The memory may not be operational. This an early indicator of a
possible future uncorrectable error.
Action
Re-seat the memory modules. If the issue persists, see
.
MEM0702
Message
Correctable memory error rate exceeded for <
location
>.
LCD Message
Correctable memory error rate exceeded for <
location
>. Re-seat
memory.
Details
The memory may not be operational. This an early indicator of a
possible future uncorrectable error.
Action
Re-seat the memory modules. If the issue persists, see
.
MEM1001
Message
Memory device at location <
location
> failed to transition to a running
state.
LCD Message
Memory device <
location
> failed to transition to a running state. Re-
seat memory
Details
The memory may not be operational. This an early indicator of a
possible future uncorrectable error.
Action
Re-seat the memory modules. If the issue persists, see
.
MEM1003
Message
Memory device at location <
location
> failed to transition to in test.
Details
The memory may not be operational. This an early indicator of a
possible future uncorrectable error.
Action
Re-seat the memory modules. If the issue persists, see
.
93