Dell PowerEdge M520 (for PE VRTX) User Manual
Page 127
Error Code
Message Information
Details
System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.
Action
1. Review system logs for power supply exceptions.
2. Remove the processor module. Inspect processor socket for
bent pins.
.
VLT0102
Message
Processor module <
name
> voltage is greater than the upper warning
threshold.
LCD Message
Processor module <
name
> voltage is outside of range.
Details
System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.
Action
1. Review system logs for power supply exceptions.
2. Remove the processor module. Inspect processor socket for
bent pins.
.
VLT0103
Message
Processor module <
name
> voltage is greater than the upper critical
threshold.
LCD Message
Processor module <
name
> voltage is outside of range.
Details
System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.
Action
1. Review system logs for power supply exceptions.
2. Remove the processor module. Inspect processor socket for
bent pins.
.
VLT0104
Message
Processor module <
name
> voltage is outside of the allowable range.
LCD Message
Processor module <
name
> voltage is outside of range.
127