Dell PowerEdge M520 (for PE VRTX) User Manual
Page 123

Error Code
Message Information
Details
Ambient air temperature is too warm or one or more fans may have
failed.
Action
The system board <
name
> temperature is outside of the optimum
range. Check Fans.
TMP0109
Message
The memory module <
number
> temperature is greater than the upper
critical threshold.
LCD Message
Memory module <
number
> temperature is outside of range. Check
Fans.
Details
Ambient air temperature is too warm or one or more fans may have
failed.
Action
The system board <
name
> temperature is outside of the optimum
range. Check Fans.
TMP0110
Message
The memory module <
number
> temperature is outside of range.
LCD Message
Memory module <
number
> temperature is outside of range. Check
Fans.
Details
Ambient air temperature is too warm or cool.
Action
Check the system operating environment.
TMP0112
Message
The <
name
> temperature is less than the lower warning threshold.
LCD Message
The <
name
> temperature is outside of range.
Details
Ambient air temperature is too cool.
Action
Check the system operating environment.
TMP0113
Message
The <
name
> temperature is less than the lower critical threshold.
LCD Message
The <
name
> temperature is outside of range.
Details
Ambient air temperature is too cool.
Action
Check the system operating environment.
TMP0114
Message
The <
name
> temperature is greater than the upper warning
threshold.
LCD Message
The <
name
> temperature is outside of range. Check Fans
Details
Ambient air temperature is too warm or one or more fans may have
failed.
123