Page 88

Error Code
Message Information
HWC4000
Message
A hardware incompatibility detected between BMC/iDRAC firmware
and CPU.
LCD Message
Incompatibility between BMC/iDRAC firmware and CPU. Update
firmware.
Details
A hardware incompatibility was detected between BMC/iDRAC
firmware and Processor(s). An iDRAC or BMC firmware update is
needed.
Action
Update the BMC/iDRAC firmware. If the issue persists, see
.
HWC4002
Message
A hardware incompatibility detected between BMC/iDRAC firmware
and other hardware.
Details
A hardware incompatibility was detected between BMC/iDRAC
firmware and other hardware. An iDRAC or BMC firmware update is
needed.
Action
Update the BMC/iDRAC firmware. If the issue persists, see
.
HWC4011
Message
Hardware unsuccessfully updated for PCIe mezzanine card
<
number
>.
Action
Check presence of the hardware, reinstall or reconnect, then
reattempt the update. If the issue persists, see
.
HWC4013
Message
Hardware unsuccessfully updated for embedded NIC.
Action
Check presence, reinstall or reconnect, then reattempt the update. If
the issue persists, see
HWC4015
Message
Link Tuning error detected.
Details
CMC has old firmware. After updating the firmware the CMC will
recognize the device.
Action
Update the CMC firmware. If the issue persists, see
.
HWC5001
Message
<
name
> is offline.
Action
If unexpected, check presence, then reinstall or reconnect.
HWC5002
Message
A fabric mismatch detected on <
name
>.
Details
The fabric type for the IOM and PCIe mezzanine cards must match.
88