Dell PowerEdge M520 (for PE VRTX) User Manual
Page 119
Error Code
Message Information
a platform event (such as power down, cycle, interrupt, and send
alert).
Action
Review platform event configuration.
SEL1211
Message
The time-stamp clock could not be synchronized.
Details
The time stamp on system event log events may not correlate to the
system time.
Action
Cycle system input power. If problem persists, contact support.
SEL1300
Message
No bootable media found.
Details
System setup displays the system boot order. The local video screen
may also show additional information. (IPMI sensor type code 1eh -
offset 00h).
Action
Check system boot settings. Check if mass storage controller
configuration settings are applicable.
SEL1302
Message
Non-bootable diskette detected.
Details
The disk in the drive is not formatted correctly or does not contain the
necessary operating system files.
Action
Replace diskette with a bootable disk.
SEL1304
Message
The PXE server not found.
Details
PXE is one way to boot a system from the network.
Action
Check the network and PXE server configuration.
SEL1306
Message
Invalid boot sector found.
Details
The disk in the drive is not formatted correctly or does not contain the
necessary operating system files.
Action
Replace diskette with a bootable disk.
SEL1308
Message
A time-out occurred while waiting for user to select a boot source.
Details
The system has failed to boot to an operating system and needs the
user to select a boot source.
Action
Select boot source within the time allowed.
SEL1501
Message
Chassis management controller (CMC) redundancy is lost.
119