Error Code
Message Information
If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.
Action
1. Review system logs for power supply exceptions.
2. Re-configure the system to minimum configuration, inspect and
reinstall system cables.
VLT0221
Message
The <
name
> voltage is greater than the upper critical threshold.
LCD Message
The <
name
> voltage is outside of range.
Details
System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.
Action
1. Review system logs for power supply exceptions.
2. Re-configure the system to minimum configuration, inspect and
reinstall system cables.
VLT0222
Message
The <
name
> voltage is outside of range.
LCD Message
The <
name
> voltage is outside of range.
Details
System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.
Action
1. Review system logs for power supply exceptions.
2. Re-configure the system to minimum configuration, inspect and
reinstall system cables.
VLT0224
Message
The memory module <
name
> voltage is less than the lower warning
threshold.
LCD Message
Memory module <
number
> <
name
> voltage is outside of range.
Details
System hardware detected an over voltage or under voltage
condition.