Dell PowerEdge M520 (for PE VRTX) User Manual
Page 102

Error Code
Message Information
Action
Cycle input power, update component drivers, remove and reinstall
the device at the next scheduled service time.
PDR0001
Message
Fault detected on drive <
number
>.
LCD Message
Fault detected on drive <
number
>. Check drive.
Details
The controller detected a failure on the disk and has taken the disk
offline.
Action
Remove and re-seat the failed disk. If the issue persists, see
.
PDR0002
Message
A predictive failure detected on drive <
number
>.
Details
The controller received a SMART error from the drive. The drive is
operational but needs replacement.
Action
The drive will need replacement at the next service window.
PDR0016
Message
Drive <
number
> is removed.
LCD Message
Drive <
number
> is removed. Check drive.
Details
The controller detected a drive removal.
Action
If unintended, verify drive installation. Remove and re-seat the
indicated disk. If the issue persists, see
.
PDR1001
Message
Fault detected on drive <
number
> in disk drive bay <
bay
>.
LCD Message
Fault detected on drive <
number
> in disk drive bay <
bay
>. Check
drive.
Details
The controller detected a failure on the disk and has taken the disk
offline.
Action
Re-seat the failed drive. If the issue persists, see
.
PDR1002
Message
A predictive failure detected on drive <
number
> in disk drive
bay<
bay
>.
Details
The controller received a SMART error from the drive. The drive is
operational but needs replacement.
Action
The drive will need replacement at the next service window.
PDR1016
Message
Drive <
number
> is removed from disk drive bay <
bay
>.
LCD Message
Drive <
number
> removed from disk drive bay <
bay
>. Check drive.
102