Dell PowerEdge M520 (for PE VRTX) User Manual
Page 112
Error Code
Message Information
RFM1006
Message
Removable Flash Media <
name
> is offline.
Details
At boot, the Card Identification (CID) signature of the card is different
from the Non-volatile (NV) storage value or the card is the destination
of a copy operation that is in-progress.
Action
If unintended, reinstall the flash media.
RFM1008
Message
Failure detected on Removable Flash Media <
name
>.
LCD Message
Removable Flash Media <
name
> failed. Check SD Card.
Details
An error was reported during a SD card read or write.
Action
Reseat the flash media, if the issue persists replace the media.
RFM1014
Message
Removable Flash Media <
name
> is write protected.
LCD Message
Removable Flash Media <
name
> is write protected. Check SD Card.
Details
The card is write-protected by the physical latch on the SD card. A
write-protected card cannot be used.
Action
If unintended, remove the media and disable write protection.
RFM1016
Message
Media not present for Removable Flash Media <
name
>.
Details
The SD card is not detected or not installed.
Action
If unintended, reinstall the flash media.
RFM1021
Message
Removable Flash Media is not IPMI-function ready.
Details
The removable flash media is installed but improperly configured or
failed to initialize.
Action
If unintended, reinstall the flash media.
RFM1022
Message
Removable Flash Media is ready.
Action
If unintended, reinstall the flash media.
RFM1023
Message
Removable Flash Media is not ready.
Details
The media is being prepared or is under maintenance. If the problem
persists, reinstall the card.
Action
If unintended, reinstall the flash media.
112