Dell PowerEdge M520 (for PE VRTX) User Manual
Page 78

Error Code
Message Information
LCD Message
Battery for disk drive bay <
bay
> is absent. Check battery.
Details
Verify the cable connection between the storage battery and the
controller.
Action
Verify the storage battery installation.
BAT0015
Message
The <
name
> battery is low.
Details
The low <
name
> battery may impact system performance negatively.
Action
Recharge the <
name
> battery if possible. If the problem continues
replace the <
name
> battery.
BAT0017
Message
The <
name
> battery has failed.
LCD Message
The <
name
> battery has failed. Check battery.
Details
The <
name
> battery is either missing, bad, or unable to charge due to
thermal issues.
Action
Check system fans. Replace the <
name
> battery.
BAT0019
Message
The <
name
> battery is absent.
LCD Message
The <
name
> battery is absent. Check battery.
Details
The failed or missing <
name
> battery may reduce system
performance.
Action
Check system fans. Replace the <
name
> battery.
CBL0006
Message
Multiple storage controllers are incorrectly connected to the same
backplane <
Bay ID
>.
Details
Unsupported backplane configuration.
Action
Check backplane configuration. Reconnect cable. If the issue
persists, see
.
CPU0000
Message
CPU <
number
> has an internal error (IERR).
LCD Message
CPU <
number
> has an internal error (IERR).
Details
System event log and OS logs may indicate that the exception is
external to the processor.
Action
Review System Event Log and Operating System Logs. If the issue
persists, see
.
CPU0001
Message
CPU <
number
> has a thermal trip (over-temperature) event.
78