Dell PowerEdge M520 (for PE VRTX) User Manual
Page 107

Error Code
Message Information
LCD Message
Incorrect memory configuration. Review User Guide.
Details
System BIOS detected an invalid memory population.
Action
Reinstall memory to match supported memory configuration.
PST0254
Message
General failure after video.
LCD Message
General failure after video. Check screen message.
Details
System BIOS detected a functional or configuration issue during
system POST.
Action
Check system video and review event log for additional information.
PST0256
Message
POST fatal error detected.
LCD Message
POST fatal error detected.
Details
System BIOS detected a functional or configuration issue during
system POST.
Action
Check system video and review event log for additional information.
PSU0001
Message
Power supply <
number
> failed.
LCD Message
PSU <
number
> failed. Check PSU.
Action
Remove and reinstall the power supply. If the issue persists, see
PSU0002
Message
A predictive failure detected on power supply <
number
>.
LCD Message
Predictive failure on PSU <
number
>. Check PSU.
Details
System performance and power redundancy may be degraded or
lost.
Action
Remove and reinstall the power supply at the next service window. If
the issue persists, see
.
PSU0003
Message
The power input for power supply <
number
> is lost.
LCD Message
Power input for PSU <
number
> is lost. Check PSU cables.
Details
The power supply is installed correctly but an input source is not
connected or is not functional.
Action
Verify the input source is attached to the power supply. Verify the
input power is within the operating requirements for the power
supply.
107