Dell PowerEdge M520 (for PE VRTX) User Manual
Page 79
Error Code
Message Information
LCD Message
CPU <
number
> has a thermal trip. Check CPU heat sink.
Details
The processor temperature increased beyond the operational range.
Action
Review logs for fan failures, replace failed fans. If no fan failures are
detected, check inlet temperature (if available) and reinstall
processor heat-sink.
CPU0002
Message
CPU <
number
> has failed the built-in self-test (BIST).
Action
1. Turn system off and remove input power for one minute.
Reapply input power and turn system on.
2. Make sure the processor is seated correctly.
3. If the issue persists, see
.
CPU0003
Message
CPU <
number
> is stuck in POST.
Action
1. Turn system off and remove input power for one minute.
Reapply input power and turn system on.
2. Reduce system configuration to minimum memory and remove
all PCI devices. If system completes POST, update system BIOS.
reinstall memory and PCI one component at a time to meet the
original configuration.
.
CPU0004
Message
CPU <
number
> failed to initialize.
Action
1. Turn system off and remove input power for one minute.
Reapply input power and turn system on.
2. Make sure the processor is seated correctly.
3. If the issue persists, see
.
CPU0005
Message
CPU <
number
> configuration is unsupported.
LCD Message
CPU <
number
> configuration is unsupported. Check CPU or BIOS
revision.
Details
System is unable to boot or may run in a degraded state.
Action
Review the technical specifcations for supported processor types.
CPU0006
Message
Unrecoverable CPU complex error detected on CPU <
number
>.
Details
System is unable to boot or may run in a degraded state.
79