Dell PowerEdge M520 (for PE VRTX) User Manual
Page 96
Error Code
Message Information
Action
Review system event log for platform events capable of shutting the
system down.
OSE0005
Message
Agent is not responding.
Details
Graceful shutdown request to an agent via the BMC did not occur
due to a system hardware or software exception.
Action
Review operating system logs and system video for additional
information.
OSE1001
Message
Failed to boot from A.
Action
Review system boot configuration and boot media. Verify the media in
a: is bootable. See system video for additional information.
OSE1003
Message
Failed to boot from C.
Action
Review system boot configuration and boot media. Verify the media in
C: is bootable. See system video for additional information.
OSE1005
Message
PXE boot failed.
Action
Review system boot configuration, local PXE configuration, and PXE
server configuration.
OSE1007
Message
Diagnostic boot failed.
Action
Review system boot configuration and boot media. See system video
for additional information.
OSE1009
Message
Failed to boot from CD-ROM.
Action
Review system boot configuration and boot media. Verify the media in
the CDROM is bootable. See system video for additional information.
OSE1011
Message
Failed to boot from ROM.
Action
Check system event logs for additional exception information. Power
down the system and attempt to boot again.
OSE1013
Message
Failed to boot.
Action
Review system boot configuration and boot media. See system video
for additional information.
96