Error Code
Message Information
Details
An action or failure has taken place that breaks CMC redundancy.
Action
Check the CMC network cables and network connections. Check that
CMC firmware versions match.
SEL1502
Message
Chassis management controller (CMC) redundancy is degraded.
Details
An action or failure has taken place that breaks CMC redundancy.
Action
Check the CMC network cables and network connections. Check that
CMC firmware versions match.
SEL1504
Message
The chassis management controller (CMC) is not redundant.
Insufficient resources to maintain normal operations.
Details
There is not enough available power for two CMC's to operate.
Action
Check the overall power consumption and power status.
SEL1506
Message
Lost communications with Chassis Group Member <
number
>.
Details
The primary CMC has lost communication with the indicated member
CMC.
Action
Check the network cable and network connections.
SEL1508
Message
Member <
number
> could not join the Chassis Group.
Details
The indicated member CMC is a leader of a different CMC stacking
group.
Action
Check if member CMC is a leader of a different chassis group.
SEL1510
Message
An authentication error detected for Chassis Group Member
<
number
>.
Details
Group master CMC could not log into the group member CMC.
Action
Check the login credentials of CMC.
SEL9900
Message
An unsupported event occurred.
Details
The current software version cannot decode this event. You may
need to review this event using a tool which displays raw data such
as Ipmitool with the -vvv option or Racadm with the -E option.
Action
Upgrade the management software.
120