Troubleshooting
Maintenance
Check the air filter as per manufacturer recommendation.
Problem
Cause
Solution
Compressor
won’t turn on
Switch turned “off”.
Turn switch “on”.
Poor electrical connection.
Clean connections and reassemble.
Fuse blown.
Replace fuse (60A).
Erratic down
pressure reading
Poor electrical connection to load
cell.
Clean connection and reassemble.
Load cell malfunction.
Replace load cell.
Persistent “high”
alarm
Row unit spring tension too high.
Lower spring tension.
Air leak preventing cylinders from
holding pressure.
Fix leak.
Persistent “low”
alarm
Row unit spring tension too low.
Raise spring tension.
System won’t
hold air
pressure
Pinched/torn hose.
Replace hose.
Hose not pushed into quick con-
nect fitting far enough.
Push hose in until fully seated.