Tweco 400 MST Arc Master User Manual
Page 37

400MST
8
Power Source Error Codes
8 – 2
10 E93 error code displayed
Memory chip (EEPROM) 
on control PCB can not 
read/write weld 
parameter.
Memory chip (EEPROM) 
error.
Have an Accredited Thermal 
Arc Service Agent check the 
control PCB.
Weld current ceases.
Buzzer sounds constantly.
Switch machine off.
11 E94 error code displayed
Temperature sensor TH1 
for IGBTs or sensor TH2 
for secondary diodes are 
open circuit.
The Welding Power Source's 
temperature sensors have 
malfunctioned.
Have an Accredited Thermal 
Arc Service Agent check or 
replace the temperature 
sensors.
Weld current ceases.
Buzzer sounds constantly.
Switch machine off.
12 E99 error code displayed
Mains supply (input) 
voltage has been turned 
off but control circuit has 
power from the primary 
capacitors.
A Main on/off switch on
machine has been turned 
off.
B Mains supply (input)
voltage has been turned 
off.
A Turn on/off switch on.
B Have an Accredited 
Thermal Arc Service 
Agent or a qualified 
electrician check the 
Mains voltage and fuses.
Weld current ceases.
Buzzer sounds constantly.
Must switch machine off then 
on to reset E99 error.
Description
Possible Cause
Remedy
Remarks