MAINTENANCE
MAINTENANCE
PAK 200
SECTION 5:
MAINTENANCE
5.01 Maintenance
Schedule
Perform the following checks periodically to ensure proper system performance.
Power Supply Maintenance Schedule
Daily
Check coolant level; add coolant as needed.
Check gas hose connections and pressures.
Check cooling fan; clean as needed.
Monthly
Check cooling fan and radiator; clean as needed.
Check gas hoses for cracks, leaks, or abrasion.
Replace as needed.
Check all electrical connections for cracks or
abrasion. Replace as needed.
Six Months
Replace coolant fi lter.
Clean coolant tank.
Vacuum out any dust buildup inside power
supply.
Table 5-1: Power Supply Maintenance Schedule
5.01 Coolant Filter Cleaning Procedure
Periodic cleaning of the coolant fi lter ensures maximum coolant fl ow effi ciency. Poor coolant fl ow causes inef-
fi cient torch parts cooling with consequent faster consumable wear.
Clean the coolant fi lter as follows:
1. Disconnect system from maintenance input power.
2. Unscrew and remove the fi lter bowl by hand. Be sure to keep the O-ring.
3. Remove and clean the fi lter. Re-install the bowl, tightening it by hand. Be sure the O-ring is in place.
4. Turn the system ON and check for leaks.