beautypg.com

Operation pak 200 – Tweco Pak 200 User Manual

Page 51

background image

OPERATION

PAK 200

Manual 0-5057 4-7 OPERATION

Status Code Key for PAK 200

Status Code

Message

Cause/Remedy

3-4

Gas Control not ready

Purging; RUN/SET in SET position;

3-5

Gas Control Protocol Fault

Does not apply to PAK-200, if displayed CCM defective.

3-6

Invalid Current Control level
from GCM

Does not apply to PAK-200, if displayed CCM defective.

3-7

Gas Control returns wrong
command sequence

Does not apply to PAK-200, if displayed CCM defective.

3-8

CCM and Gas Control type
(Autocut-Ultracut) mismatch

CCM not PAK-200 (SW13-1 should be OFF) or CCM defective.

3-9

Gas Control Communication
reply fault

Does not apply to PAK-200, if displayed CCM defective.

3-10

Warning. -- Gas Control fi rm-
ware needs update

Does not apply to PAK-200, if displayed CCM defective.

4-1

Coolant Level low fault

Check coolant level, add as needed.

4-2

Low coolant fl ow after power
on purge. < 0.4gal/min;

Suction leak introducing air into coolant, suspect rear panel fi lter
seal; clogged fi lter; defective pump.

4-3

C o o l a n t o v e r h e a t e d
(>70 deg. C, 158 deg F)

Coolant fan failed; radiator fi ns clogged with dirt; Ambient tem-
perature > 40 deg C.

4-4

Coolant System not ready.

During power on purge / prim-
ing, fl ow did not reach 0.4 gal/
min for at least 5 seconds

If new installation recycle power to restart pump, may take a
few times to fi ll hoses;

Damaged torch coolant tube; Suction leak introducing air into
coolant, suspect rear panel fi lter seal; clogged fi lter; defective
pump.

4-5

Low Coolant Level - Warning

While cutting, detected low coolant level, does not stop cut.

Add coolant as required.

5-1

CANBUS Failure to Acknowl-
edge fault.

Does not apply to PAK-200, if displayed CCM defective.

5-2

CANBUS OFF due to excessive
data errors;

Does not apply to PAK-200, if displayed CCM defective.

5-3

CANBUS data error warning.

Errors increasing, will soon
fault.

Does not apply to PAK-200, if displayed CCM defective.

5-4

CCM Message not sent

Does not apply to PAK-200, if displayed CCM defective.

6-1

CCM Analog Voltage Error

Replace CCM

6-2

CCM ADC or DAC error

Replace CCM

6-3

Coolant Flow too High error,
fl ow > 2.7 gal/min

Torch coolant tube broken or missing;

CCM fault, replace CCM

6-4

CCM Data Memory error

Replace CCM

Table 4-8: Status Code Key for PAK 200