Manual 0-5057

3-11

INSTALLATION

INSTALLATION

PAK 200

CAUTION

Printed circuit boards in the Command - Control Module are static - sensitive. Discharge any built-up

static charges in your body or surroundings before touching the printed circuit boards.

SW-6: OK-to-Move: Contact closure, 120VAC @ 1A (Factory default setting) or
DC Volts (16-18vdc@ up to 100 ma.)

SW-11: Analog Current Control. B = from Gas Control (Factory default setting) or A = from CNC.
Position A requires that SW-8-2 be ON.

SW-12-1/2/3/4: Divided Arc signal

All = OFF = 50:1 (Factory default setting)

1 = ON = 16.6:1
2 = ON = 30:1
3 = ON = 40:1
4 = Not used.


SW13-1:

1 = OFF


SW13-2:

1 = ON

Art # A-08502_AB

Only 1 on at a time.

SW11

SW13

SW6

SW12

No external
connection cover

Figure 3-11: Set Switches 2

NOTE

Standoff Control SC-11 requires Switch 12-1 set to