PAK 200

OPERATION

OPERATION 4-6 Manual 0-5057

Status Code Key for PAK 200

Status Code

Message

Cause/Remedy

1-1

System not Enabled or Miss-
ing AC Input Phase

External E-Stop Activated or CCM TB1-1&2 jumper missing;
Missing AC Phase; GCM200 control cable not connected.

1-2

Pilot Ignition Failure

Pilot did not start within 15 seconds.

Plasma pressure too high; Defective Arc Starter

1-3

Lost Pilot

Pilot went out without shutoff signal; Plasma pressure too high;
cut current set too low for consumables.

1-4

Loss of Transfer

Arc transfer (>50 ms.) then arc lost with START still on. Standoff
too high; Current set too low.

1-5

Of the Plate

Function not currently enabled.

1-6

Pilot Timed out w/o Transfer

Must transfer from Pilot to Cutting Arc in 85ms. (SW8-1 OFF) or 3
sec. (SW8-1 ON). Standoff too high or void in work under torch;
cut current too low for consumables; Plasma pressure too low.

1-7

Not used

1-8

Tip to Electrode Voltage too
low

Detected tip voltage too close to electrode voltage. Plasma fl ow/
pressure too low; Plasma leak; cut current too high; shorted
torch body; consumable parts worn out.

2-1

Missing Phase

Blown fuse, Broken or loose connection on power cable

2-2

Wrong input voltage

Inverter(s) not confi gured correctly for input voltage;

Poor power quality (brownouts, dropouts);

Input power capacity / wiring too small causing voltage drop;
broken or loose power cable connections.

2-3

Inverter or Pilot Regulator
Over Temperature

Failed fan; Ambient above 40 deg C. (104 F); Blocked airfl ow

2-4

Power Supply not Ready

Defective inverter

2-5

DC Output Low

Output less than 60VDC; Defective inverter, shorted output;
Shorted pilot regulator (chopper); CCM voltage sense (J6) wire
open or disconnected.

2-6

Inverter primary over current
or cap voltage imbalance fault

Over current detected in inverter primary circuit, remove power
to reset; defective inverter; voltage surge;

2-7

Unexpected current

Current >20A in work or pilot leads before pilot ignition; Possible
shorted torch; Defective current sensor.

2-8

Unexpected current in pilot
circuit

Current > 5A in pilot circuit; wrong or mismatched consumables;
Pilot lead shorted to negative in torch tube; Possible shorted torch

2-9

Unexpected current in work
lead

Current > 5A in work lead; Short to chassis in RAS; Negative
lead short to ground.

3-1

Gas Control Communication
fault

,

Cannot establish Com-

munication with gas control.

GCM 200 Control cable not connected or Basic ID signal open;

CCM not PAK 200 (SW13-1 should be OFF) or

CCM defective, replace.

3-2

Gas Control Communication
reply fault

,

Does not apply to PAK-200, if displayed CCM defective.

3-3

Gas Pressure Low

Plasma < 51 PSI; faulty or disconnected pressure SW.