Rockwell Automation 20D PowerFlex 700S and 700H Frame 10...12 Rectifier Module Replacement Kit User Manual
Page 46

46
Important: If the drive fails any of these measurements, verify that all
connections have been properly made for the appropriate rectifier
module.
Series B Rectifier Circuit Board - Rectifier Module Tests
Important: If the drive fails any of these measurements, verify that all
connections have been properly made for the appropriate rectifier
module.
Table B Reverse Biased Diode Tests on Rectifier Module(s)
Meter Leads
Nominal meter reading
+
-
1L1
DC-
Meter should display “.0L” (zero load)
1L2
DC-
1L3
DC-
DC+
1L1
DC+
1L2
DC+
1L3
Table C Forward Biased Diode Tests on Rectifier Module(s)
Meter Leads
Nominal meter reading
-
+
DC+
1L1
Meter should beep once and value should gradually rise to about 1.0 V
(1)
(1)
The actual voltage reading may vary depending upon your equipment. If your readings are not near 1.0V, verify
that the actual voltage measured is consistent for the Rectifier module and the Output Power modules.
DC+
1L2
DC+
1L3
1L1
DC-
The value should gradually rise to about 0.35V
(2)
(2)
The actual voltage reading may vary depending upon your equipment. If your readings are not near 0.35V,
verify that the actual voltage measured is consistent for the Rectifier module and the Output Power modules.
1L2
DC-
1L3
DC-
Table D Reverse Biased Diode Tests on Rectifier Module(s)
Meter Leads
Nominal meter reading
+
-
1L1
DC-
Meter should display “.0L” (zero load)
1L2
DC-
1L3
DC-
DC+
1L1
DC+
1L2
DC+
1L3