beautypg.com

Rockwell Automation 20D PowerFlex 700S and 700H Frame 10...12 Rectifier Module Replacement Kit User Manual

Page 46

background image

Publication PFLEX-IN023A-EN-P

46

Important: If the drive fails any of these measurements, verify that all

connections have been properly made for the appropriate rectifier
module.

Series B Rectifier Circuit Board - Rectifier Module Tests

Important: If the drive fails any of these measurements, verify that all

connections have been properly made for the appropriate rectifier
module.

Table B Reverse Biased Diode Tests on Rectifier Module(s)

Meter Leads

Nominal meter reading

+

-

1L1

DC-

Meter should display “.0L” (zero load)

1L2

DC-

1L3

DC-

DC+

1L1

DC+

1L2

DC+

1L3

Table C Forward Biased Diode Tests on Rectifier Module(s)

Meter Leads

Nominal meter reading

-

+

DC+

1L1

Meter should beep once and value should gradually rise to about 1.0 V

(1)

(1)

The actual voltage reading may vary depending upon your equipment. If your readings are not near 1.0V, verify
that the actual voltage measured is consistent for the Rectifier module and the Output Power modules.

DC+

1L2

DC+

1L3

1L1

DC-

The value should gradually rise to about 0.35V

(2)

(2)

The actual voltage reading may vary depending upon your equipment. If your readings are not near 0.35V,
verify that the actual voltage measured is consistent for the Rectifier module and the Output Power modules.

1L2

DC-

1L3

DC-

Table D Reverse Biased Diode Tests on Rectifier Module(s)

Meter Leads

Nominal meter reading

+

-

1L1

DC-

Meter should display “.0L” (zero load)

1L2

DC-

1L3

DC-

DC+

1L1

DC+

1L2

DC+

1L3

This manual is related to the following products: