12. The V and W phase modules must be removed from the power structure in

order to remove the rectifier modules. Therefore, you must lift the power
structure off the maintenance stand and place it, rear side of the unit down,
on a clean, suitable work surface. Follow the steps below to lift and move
the power structure.

a. Fasten the lifting hardware to the holes in the flanges on the top of the

power structure, symmetrically, in at least two holes. The maximum
angle between the cables must be no more than 45 degrees.

b. Lift the power structure off of the maintenance stand and place it, rear

side down, on the work surface.

Maximum angle
45 degrees

210 kg (463 lb)

Note: Power structure shown with
protective covers. Complete the
previous steps to remove the covers
and disconnect control wiring before
lifting and moving the power structure.