beautypg.com

Rockwell Automation 20D PowerFlex 700S and 700H Frame 10...12 Rectifier Module Replacement Kit User Manual

Page 25

background image

25

Publication PFLEX-IN023A-EN-P

5. Carefully disconnect the fiber-optic cables from sockets H15 and H16 on

each of the three gate driver boards and carefully set them aside (see
illustration below).

Important: Minimum inside bend radius for fiber-optic cable is 25.4 mm (1.0

in.). Any bends with a shorter inside radius can permanently
damage the fiber-optic cable. Signal attenuation increases with
decreased inside bend radii.

6. Remove the cables from connectors X6 and the DC+/DC- terminals from

the connector at the bottom of the three gate driver boards.

ATTENTION: Hazard of permanent eye damage exists when
using optical transmission equipment. This product emits intense
light and invisible radiation. Do not look into fiber-optic ports or
fiber-optic cable connectors.

X6

H16

H15

+ -

Fiber Optics

Gate driver
board locations

Remove wires from terminals: +

This manual is related to the following products: