30. Remove the bus bars and insulator sheets - the steps to remove the bus bars

from a 400/480V AC input drive are different than the steps to remove the
bus bars from a 600/690V AC input drive. Refer to Remove the Bus Bars
from a 400/480V AC Input Drive
below or Remove the Bus Bars from a
600/690V AC Input Drive on page 41
.

Remove the Bus Bars from a 400/480V AC Input Drive

Remove the six M6x20 POZIDRIV screws that secure the outer bus bar
to the drive and remove the bus bar and the loose bus bar insulator
sheet.

Remove the three M6x20 POZIDRIV screws that secure the main DC-
bus bar to the drive and remove the main DC- bus bar and the loose bus
bar insulator sheet.

Remove the three M6x20 POZIDRIV screws that secure the main DC+
bus bar to the drive and remove the main DC+ bus bar and the loose
capacitor insulator sheet.

Outer Bus Bar

PZ3
5.0 N•m
(44.2 lb•in)

DC- Bus Bar

PZ3
5.0 N•m
(44.2 lb•in)

DC+ Bus Bar

PZ3
5.0 N•m
(44.2 lb•in)

Bus bar insulator sheets

Capacitor insulator sheet

Do Not reuse this
insulator sheet.
Replace with new
insulator sheet.