Ppendix – Rockwell Automation GV3000/SE 230VAC 30-100HP GP & Vector Drive V6.04 Start-Up and Reference Manual User Manual
Page 199

C-1
Power Module-Dependent Parameter Values
Second Menu General Parameters (USA Defaults)
Parameter
Name
Carrier
Frequency (kHz)
Parameter
No.
P.047
30V2060
4
50V2060
4
75V2060
4
100V2060
4
Note: The drives can use any carrier frequency of 2, 4 or 8 kHz. But when 8 kHz of carrier frequency is used, the drive's rated output current is
automatically limited to 80%.
A
PPENDIX
C
Power Module-Dependent Parameter
Default Values (230 V Series)
Power Module
Second Menu Volts/Hertz Parameters (USA Defaults)
Parameter
Name
Motor Nameplate
Amps
Parameter
No.
H.002
40V2060
97.4
50V2060
125.0
75V2060
170.0
100V2060
224.0
Power Module
Second Menu Vector Parameters (USA Defaults)
Parameter
Name
Motor Nameplate
Amps
Motor Nameplate
RPM
Magnetizing Current
Speed Reg. Prop.
Gain
Speed Reg. Int. Gain
Torque Reg. Prop.
Gain
Torque Reg. Int. Gain
Field Weakening
Start RPM
Motor Top Speed
Flux Current Reg.
Prop. Gain
Flux Current Reg. Int.
Gain
Rotor Time Constant
Motor Nameplate HP
SVC Flux Current
Reg. Gain
Parameter
No.
U.004
U.005
U.006
U.012
U.013
U.014
U.015
U.016
U.017
U.019
U.020
U.021
U.022
U.032
30V2060
71.0
1770
44.0
5.00
5.00
0.40
200.0
1770
1770
0.15
50.0
250
30.0
800
50V2060
125.0
1775
44.0
5.00
5.00
0.40
200.0
1775
1775
0.15
50.0
250
50.0
700
60V2060
130.0
1780
49.0
5.00
5.00
0.40
200.0
1780
1780
0.15
50.0
250
60.0
650
100V2060
177.2
1780
35.0
5.00
5.00
0.40
200.0
1780
1780
0.15
50.0
250
100.0
550
Power Module
40V2060
4
60V2060
4
30V2060
71.0
60V2060
136.0
40V2060
97.4
1775
47.0
5.00
5.00
0.40
200.0
1775
1775
0.15
50.0
250
40.0
750
75V2060
154.0
1780
46.0
5.00
5.00
0.40
200.0
1780
1780
0.15
50.0
250
75.0
600