P.020), P.008), P.009) – Rockwell Automation WebPak 3000 User Guide User Manual
Page 45

Using Quick Start
5-9
TOP
LINE
SPEED
(P.020)
Specifies the
maximum line speed
in feet per minute.
Parameter Range:
0 to 5000
FPM
Default Setting:
500
FPM
Parameter Type:
Configurable
!
ATTENTION: Do not allow the motor to exceed the maximum safe speed
of the motor or driven equipment as determined by the equipment
manufacturer. Failure to observe this precaution could result in bodily
injury.
MOTOR
RATED
ARM
AMPS
(P.008)
Identifies the rated
armature current as
is appears on the
motor nameplate.
Parameter Range:
0 to 3000.0
AMPS
Default Setting:
8.0
AMPS
Parameter Type:
Configurable
!
ATTENTION:
MOTOR
RATED
ARM
AMPS
(P.008) must be less than the
motor rated armature amps or drive current rating listed on the motor
nameplate. If this is configured incorrectly, overcurrent or excess heating
of the motor could result. Failure to observe this precaution could result
in damage to, or destruction of, the equipment.
MOTOR
RATED
ARM
VOLTS
(P.009)
Identifies the rated
armature voltage as it
appears on the motor
nameplate.
Parameter Range:
160 to 1000
VOLTS
Default Setting:
240
VOLTS
Parameter Type:
Configurable
!
ATTENTION: The incorrect configuration of
MOTOR
RATED
ARM
VOLTS
(P.009) can cause an overspeed condition. This parameter must be
configured by a qualified person who understands the significance of
configuring it accurately. Failure to observe this precaution could result
in bodily injury.