Rockwell Automation WebPak 3000 User Guide User Manual
Page 34

4-8
WebPak 3000 OIM User Guide
The
PASSWORD
parameter toggles the program protection setting. If program
protection is enabled, this procedure disables it. If disabled, the procedure enables it.
To enable or disable software program protection:
Step 1. Press
until the
indicator reads
PROGRAM
and “WebPak 3000
Main Menu” is displayed at the top of the screen.
Step 2. Select the Operator Interface menu.
Step 3. Select the
PASSWORD
parameter.
•
If program protection is currently disabled: The message “Do you wish to
enter the password to
ENABLE
program protection?” is displayed.
•
If program protection is currently enabled: The message “Do you wish to
enter the password to
DISABLE
program protection?” is displayed.
Step 4. Select
YES
or
NO
. Press
.
•
YES
: Changes the setting. The screen shown in figure 4.10 is displayed.
Go to step 5.
•
NO
: Keeps the current setting. You are returned to the Operator Interface
menu and no change is made.
Step 5. Press
to change the value to 55. (You cannot set a different password.)
Press
. You are returned to the Operator Interface menu and the
PASSWORD
setting is changed.
Step 6. To save changes to the
PASSWORD
parameter through a power cycle, the
configuration must be saved using the WebPak CS software. See the
WebPak CS software manual for information.
Figure 4.10 – PASSWORD Parameter Entry Screen