Rockwell Automation FactoryTalk View Site Edition Installation Guide User Manual
Page 56

F
ACTORY
T
ALK
V
IEW
I
NSTALLATION
G
UIDE
42
• •
•
•
•
Enter and verify the password, then click Next.
Strong Password Guidelines
Strong passwords are not readily guessed by a person, and are not easily hacked using a
computer program. Strong passwords cannot use prohibited conditions or terms,
including:
A blank or NULL condition
Password
Admin
Administrator
sa
sysadmin
A strong password cannot be the following terms associated with the installation
computer:
The name of the user currently logged onto the machine
The computer name
A strong password must be more than 8 characters in length and satisfy at least three of
the following four criteria:
It must contain uppercase letters
It must contain lowercase letters
It must contain numbers
It must contain non-alphanumeric characters; for example, #, %, or ^
Install other compatible SQL Server editions
FactoryTalk View Site Edition provides a batch file that you can use to install the SQL
Server edition with minimal user intervention. Follow the steps below:
1. Close all open Windows programs, including FactoryTalk View setup program.
2. Open the Command Prompt window:
The chosen password should be recorded and saved along with other administrator passwords
for system maintenance personnel.
FTViewSEInstallENU.book Page 42 Wednesday, July 16, 2014 10:53 AM