Line filter module specifications, English – Rockwell Automation SP120 ACDrive 115VAC, 1Ph, 230VAC, 1Ph/3Ph, 1/4-5.0HP User Manual
Page 66

A-10
SP120 AC Drive Installation and Operation
English
Line Filter Module Specifications
Current: at 40 °C ambient temperature
Overload: 150% IN for 10 min
Frequency: 50/60 Hz
Material: steel, surface refined
Humidity class: C
Operation height: < 1000 m without derating
> 1000 m, I
N
-2%, for each 1000m
Temperature range: -25 °C to +85 °C
Connections: Input terminals IP 20 and PE-screw M5
Load side: cable, unshielded
Line Filter
Module
Nominal
Voltage
(V)
Nominal
Current at
40
°
C (A)
Leakage
Current at
50 Hz
(mA)
Test voltage
(VDC for 2 sec)
ph./ph.;
ph./ground
Input wire max.
cross section
(mm
2
)
L/N
Output cable
cross section
(mm
2
)
Heat
dissipation
(W)
S12-MF1-1010 100-120
10
< 3.5
N/A
4/4
3x1.5
N/A
S12-MF1-1016 100-120
16
< 3.5
N/A
4/4
3x1.5
N/A
S12-MF1-Y007 200-240
7
< 3.5
1400 / 2800
4/4
3x1.5
6
S12-MF1-Y012 200-240
12
< 3.5
1400 / 2800
4/4
3x1.5
7
S12-MF1-Y022 200-240
22
< 10
1400 / 1400
4/4
3x2.5
9
S12-MF1-2004 200-240
4
< 3.5
1400 / 2800
4/4
4x1.5
N/A
S12-MF1-2007 200-240
7
< 3.5
1400 / 2800
4/4
4x1.5
N/A
S12-MF1-2020 200-240
20
< 3.5
1400 / 1400
4/4
4x2.5
N/A
S12-MF1-4007 380-460
7
< 3.5
1978 / 2800
4/4
4x1.5
7
S12-MF1-4011 380-460
11
< 3.5
1978 / 2800
4/4
4x2.5
10
0
0,2
0,4
0,6
0,8
1,0
20
40
60
80
100
Temperature in °C
0
I
B
I
N
1,2
Dependence of current on ambient temperature