Hapter, Introduction, 1 conventions used in this manual – Rockwell Automation SP120 ACDrive 115VAC, 1Ph, 230VAC, 1Ph/3Ph, 1/4-5.0HP User Manual
Page 11: 2 model number description
Introduction
1-1
English
C
HAPTER
1
Introduction
This chapter describes the SP120 AC drive and how to identify it based on its model
number. It also provides receiving information and a description of the drive
nameplate and other features.
Refer to Appendix A for specifications and mounting dimensions for the SP120 line
filter modules.
1.1
Conventions Used in This Manual
To help differentiate parameter names and parameter settings from other text
the following conventions will be used:
•
Parameter numbers and names are shown in the following way:
d01 [
OUTPUT
FREQUENCY
]
•
Parameter settings for inputs and outputs are shown with the setting number
followed by the alpha description in {braces}. For example, 18{RS}.
1.2
Model Number Description
Figure 1.1 below describes the SP120 AC drive model numbering structure. Note that
not all combinations can be configured as a drive. Refer to Appendix A,
Technical
Specifications, for more information.
Figure 1.1 – Model Number Structure
S12 - 2 0 1P4 L U
S12 = SP120
Voltage Rating
1 = 115 VAC (
1φ
)
2 = 230 VAC (
1φ
or
3φ
)
4 = 460 VAC (
3φ
)
Enclosure Type
0 = protected chassis IP20
Output Current
1P4 = 1.4 A (0.25 HP (0.2 kW) @ 230 V) 5P0 = 5.0 A (1.5 HP 1.1 kW) @ 230 V)
1P5 = 1.5 A (0.5 HP (0.4 kW) @ 460 V) 5P5 = 5.5 A (3 HP (0.4 kW) @ 460 V)
2P5 = 2.5 A (1 HP (0.75 kW) @ 460 V) 7P1 = 7.1 A (2.0 HP (1.5 kW) @ 230 V)
2P6 = 2.6 A (0.5 HP (0.4 kW) @ 230 V) 8P6 = 8.6 A (5 HP (3.7 kW) @ 460 V)
3P0 = 3.0 A (0.75 HP (0.55 kW) @ 230 V) 010 = 10 A (3.0 HP (0.4 kW) @ 230 V)
3P8 = 3.8 A (2 HP (1.5 kW) @ 460 V) 015 = 15 A (5.0 HP 3.7 kW) @ 230 V)
4P0 = 4.0 A (1.0 HP (0.75 kW) @ 230 V)
L = Keypad
D = DeviceNet
U = 60 Hz (Default)