Troubleshooting
Chapter 8
Access Maintenance Operations
Follow these steps to access Maintenance actions at startup.
1. Insert a thin, nonconductive probe into the hole marked Default on the
back of the logic module and press the switch.
The terminal restarts in Maintenance mode with the display brightness set
to 100%. Refer to
Table 86 on page 170
for a description of maintenance
operations.
TIP
Terminals require an attached USB keyboard to navigate in Maintenance mode.
TIP
To access this menu from a fault state, press the Reset switch, then press and
hold the Default switch until you see the menu.
COMM
FAULT
DEFAUL
T
RESET
COMM
FAULT
DEFAULT
RESET
Initial Maintenance Window
default button pressed, please select maintenance options
Maintenance Menu -- ver 0x.xx
Special BOOT Action - None
Display resolution - AUTO
Continue booting with selected options
Continue with this system boot
This option will continue booting
with the options selected on the
left.
- IMPORTANT--------------------------
USB keyboard required!
Press the RESET switch to ignore
changes and continue system boot.
The version refers to the
boot loader.
TIP
Use the keys at the bottom of window to make selections.