![background image](/manuals/579929/251/background.png)
Appendix D
Troubleshooting
D-2
For unrecognizable messages, ER is set along with an error code. The
error codes are:
Code
Explanation
0000H
Success
0001H
Invalid ASCII message format
0002H
Invalid file type
0003H
invalid file number
0004H
Invalid file element
0005H
Invalid VME address
0006H
Invalid VME transfer width
0007H
Invalid number of elements requested for transfer
0008H
Invalid VME interrupt level
0009H
Invalid VME interrupt status-id value
000AH
VMEbus transfer error (bus error)
000BH
Unable to assert requested interrupt (already pending)
000CH
Raw data transfer setup error
000DH
Raw data transfer crash (PLC switched out of run mode)
000EH
Unknown message type (message type not ASCII)
Code
Explanation
01H
VMEbus transfer error (bus error)
07H
Bad data address
FDH
Bad data transfer length
FEH
Unacknowledged end-of-copy interrupt
These are the command-protocol codes placed in the error-code field of the
command control register when the ERR bit is 1.
Code
Explanation
00H
No error
01H
Invalid value in command register
02H
Cannot access first word of command block (usually a VMEbus bus error)
03H
Cannot access other than first word of command block
04H
Cannot write response word in command block