Rockwell Automation Publication 1732E-UM004A-EN-E - July 2012

Chapter 6 Troubleshoot the Module

Check for Faults

In addition to the status indicators on the module, RSLogix 5000 software alerts
you to fault and other conditions in one of three ways:

Indicator Status for the Modules

Indicator

Status

Description

Module
status

Off

No power applied to the device.

Flashing red/
green

The module is performing POST (Power-On Self Test), which
completes within 30 s.

Green

Device operating normally.

Flashing red

Module has experienced a recoverable fault. Possible minor
faults include the following:

IP Address switches do not match configuration in use.

The device has completed a reset to factory default request

due to the switches being set to 888 at power up, and a
power cycle is required.

The device is performing a firmware flash update.

Channel fault

No auxiliary power

Red

Unrecoverable fault – may require device replacement.

Network
status

Off

The device is not initialized or the module does not have an IP
address.

Flashing green

The device has no CIP connections. The device has an IP address,
but no CIP connections are established.

Green

Device is online, has an IP address. CIP connections are
established.

Flashing red

One or more connections have timed out.

Red

The module has detected that its IP address is
already in use.

Flashing red/
green

The module is performing a power-on self test (POST).

Network link
status
(Link 1/Link 2)

Off

No link established.

Green

Link established on indicated port at 100 Mbps.

Flashing green

Link activity present on indicated port at 100 Mbps.

Yellow

Link established on indicated port at 10 Mbps.

Flashing yellow

Link activity present on indicated port at 10 Mbps.

Auxiliary
Power status

Off

Auxiliary power off or not connected.

Green

Auxiliary Power applied to device.

I/O status

Off

The input channel is inactive, can be calibrated.

Flashing Green

Channel is calibrating.

Green

Normal operation, inputs being scanned.

Flashing Yellow

Thermistor fault.

Flashing Red

Fault. Overrange, underrange, or process alarm is present.

Red

No power is detected.