Configure Your Thermocouple and RTD Input Modules with RSLogix 5000 Software Chapter 3

2.

On the Select Module Type dialog that appears, select the
1732E-IT4IM12R module. Click Create.
To look for the 1732E-IT4IM12R module in the list, you can type the
catalog number in the search box or use the filters. To do so, click Clear
Filters and check Analog in the Module Type Category Filters.

3.

The New Module dialog appears.
Fill in the Module Properties information as shown, and then click OK.

TIP

If the 1732E-IT4IM12R, 1732E-IR4IM12R modules are not listed
under the analog category of the Select Module Type dialog you
may need to download the Add-On Profile (AOP) for the 1732E
ArmorBlock 2-Port and install it as an add-on to RSLogix 5000.
The AOP file can be downloaded from:

support.rockwellautomation.com/controlflash/LogixProfiler.asp