Appendix b, Wim parameters, About parameter numbers – Rockwell Automation 22-WIM-N1 DSI Wireless Interface Module User Manual
Page 57: Parameter list, Meters, refer to, Refer to, Parameters, Bwim parameters, Appendix

Appendix
B
WIM Parameters
Appendix B presents information about the WIM parameters.
The parameters in the WIM are numbered consecutively. You can use the
following configuration tools to access the parameters in the WIM.
Topic
Page
About Parameter Numbers
Configuration Tool
Numbering Scheme
• Pocket DriveExplorer for Pocket PC
• DriveExplorer
• DriveExecutive
• HIM
The adapter parameters begin with parameter
01. For example, Parameter 01 - [Adapter
Cfg] is parameter 01 as indicated by this
manual.
Parameter List
No.
Name and Description
Details
01
[Adapter Cfg]
Sets the operating mode of the WIM.
Default:
0 = Auto
Values:
0 = Auto
1 = Master
2 = Slave
3 = RTU Master
Type:
Read/Write
Reset Required: Yes
02
[Adapter Type]
Displays the present operating mode of the WIM.
Default:
0 = Master
Value:
0 = Master
1 = Slave
2 = RTU Master
Type:
Read Only
03
[Drive Addr Cfg]
Sets the node address of the WIM for use with the WIM
operating mode set with Parameter 01 - [Adapter
Cfg]. In Auto, Master or Slave mode, the WIM node
address can be any valid value. In RTU Master mode,
the WIM node address must match the address of any
drive on the network. Each network drive address, set
using drive parameter 104 - [Comm Node Addr], must
be unique.
Default:
1
Minimum:
1
Maximum:
247
Type:
Read/Write
Reset Required: Yes